EMF Range : Air Cooled Heat Exchanger for Fluid Couplings |
|||||||
| MODEL NO | HEAT
LOAD KCAL/HR
|
OIL
FLOW LPM |
APPROXIMATE OVERALL SIZE |
FAN | |||
| HEIGHT mm |
WIDTH mm |
THICK- NESS mm |
DIA mm |
MOTOR HP |
|||
| EMF 01 | 25,500 | 100 | 1140 | 900 | 800 | 550 | 0.5 |
| EMF 02 | 28,500 | 100 | 1240 | 900 | 800 | 600 | 0.75 |
| EMF 03 | 55,500 | 200 | 1500 | 1175 | 900 | 750 | 1.5 |
| EMF 04 | 70,500 | 200 | 1700 | 1375 | 950 | 850 | 1.0 |
| HEAT EXCHANGERS INCLUDES : Oil cooler Complete with Fan Shroud, Fan, Fan Adapter, Electric Motor, Fan Guard and Supporting Structure. | |
| PERFORMANCE BASED ON | |
| Oil Inlet Temp. to Oil Cooler | 90oC Max. |
| Ambient Temp | 45oC Max |
| Oil Pressure drop | <1 Bar |
| Test Pressure | 12 Bar |
| Fan Rpm | 1440 |
| We Reserve the Right to Improve the Technical Design | |
| EMH Range : Air cooled heat exchanger for Hydraulic systems | |
| EMQ Range : Air cooled heat exchanger for Quenching process | |
| Required Info | Required Quote |